Radiology Room |
Ultrasound Room |
Surgery Room |
Laboratory Room |
Comprehensive Room |
Pediatrics Room |
Dental Room |
Medical operation instruments |
Hospital Furniture |
Medical supplies |
10-100MA x ray machine
100mA medical mobile x ray machine
GENERAL
1. Used in ward and emergency treatment room for radiography.
2. Combined x-ray generator.
3. Single focus, bridge rectification.
4. It is precise safe, reliable and flexible.
5. Remote control device(control range≥5m)is used.
Unit Configuration
Control table, HT generator unit, Ht cable, X-ray tube unit
Main Characteristics
1. Single table and single tube.
2. Design according to the electric mechanism of middle-size machine ,The function is reasonable.
3. The high-tension system is of march-past structure. Equipped with afullwave rectification high-voltage generator and independent X-ray tube unit, with large output power and reliable and stable operation.
4. Supply voltage (V), roentgenoscopy, radiography (kv) and stepless adjust able.
5. Equipped with the manostat for filament of X-ray tube and the spacecharge compensator as to ensure the stable and accurate output.
6. Equipped with the capacity limitation and portection circuit and KV mA S interlock limitation and protection.
7. Adopt the digial circuit timer, grade according to R10 priority coefficient and can control time exactly.
8. Diagnostic table is of electric back rotation and is equipped with vibrating filter-ray device.
9. The spot film device of luminescent serene can hold the film jecket of various sizes and can make the photography of full-film and two sectional films separateiy.
10. The column has the bottom track only, which is easy while installation.
MIN TECHNICAL INDEXES
X-ray generator |
Stationary anode, single focus and bridge silicon rectification. |
||||
The x-ray generator is an oil-immersed self-cooled unit. |
|||||
Max rated capacity |
Current |
15mA |
30mA |
60mA |
100mA |
Voltage |
90kvp |
90kvp |
90kvp |
80kvp |
|
Time |
6.3s |
6.3s |
4.0s |
3.2s |
|
Power supply |
Voltage |
180-240V |
|||
Frequency |
50Hz |
||||
Capacity |
Not over than 7KVA |
||||
Intemal resistance |
Not larger than 1Ω |
||||
Voltage adjustment range of x-ray tube |
50-90KV |
||||
Range of the time |
0.08-6.3s |
||||
Distance between the focus to the ground |
700-1780mm |
||||
X-ray tube focus transverse rotation |
±60° |
||||
Specification of x-ray tuble |
Model XD42.9/100 fixed anode, single focus 1.8/4.3mm |
||||
Transport dimension(L×W×H)(mm) |
1230×900×2050 |
||||
Weight(kg) |
Net:159/gross:256 |